CONTEC CA10S Capnograph Sidestream Method
£257.14 Add to cart

CONTEC CA10S Capnograph Sidestream Method

£257.14

992 in stock

Free worldwide shipping on all orders over $50

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

1.1 Introduction

Capnograph adopts sidestream method to measure the end-tidal carbon dioxide, airway respiration rate and other parameters. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow as well as indirectly reflect the alveolar ventilation standard. Meanwhile, it can also detect the blood oxygen saturation and pulse.

The Capnograph is applicable for use in pre-hospital emergency transfer, emergency department, ICU, operating room, neonatology, respiratory department and other occasions. The application population is adult, pediatric and neonate patients.


 Features

1) End-tidal CO2 measurement function

2) Respiration rate measurement function

3) SpO2 measurement function

4) Pulse rate measurement function

5) Over-limit alarm function for EtCO2、Respiration rate,SpO2 and Pulse rate

6) Low battery alarm function

Performance

End-tidal CO2 measurement:

1)Measurement range: 0 ~150mmHg

2)Resolution: 1mmHg

3)Accuracy:

0~40 mmHg:±2 mmHg

41~70 mmHg:±5% of readings

71~100 mmHg:±8% of readings

101~150 mmHg:±10% of readings

Respiration rate measurement:

1)Measurement range: 2rpm~120rbpm

2)Resolution: 1rpm

3)Accuracy: ±1rpm

SpO2 measurement:

1) Measurement range: 30~100 %

2) Resolution: 1%

3) Accuracy:

70~100 %:2 %

0~69 %:undefinition

Pulse rate measurement:

1) Measurement range: 25~250 bpm

2) Resolution: 1bpm

3) Accuracy: ±2 bpm or ±2%,whichever is greater

Safety characteristic:

1)Device type: internally powered equipment

2)Degree of protection against electric shock: type BF applied part

3)Degree of protection against ingress of liquid: IPX1


Accessories

User Manual

Blood oxygen probe

Sampling pipe

 Physical Characteristic

Dimension: 159*72*31 mm

Weight: 270 g

Working environment

Temperature: 5℃~40℃

Relative humidity: 30%~ 75%, no condensation

Atmospheric pressure: 700hPa~1060hPa

Power supply: DC 3.7V (rechargeable lithium battries)

Input power: ≤1.5VA

 Optional configuration

None.

 Certification

 Selling points analysis

1. 2.8'' color LCD screen, user-friendly interface, easy to operate

2. Compact and portable design

3. Visual and audible alarm system

4. Alarm limits and unit can be set

5. With automatic compensation of atmospheric pressure

6. Suitable for use in medical transfer, emergency, surgery, monitoring and other situations

Reviews

There are no reviews yet.

Be the first to review “CONTEC CA10S Capnograph Sidestream Method”

Your email address will not be published. Required fields are marked *